British Standards for Water Tanks and Storage Compliance
Navigating water storage regulations requires looking beyond a single document. While BS EN 13280 is the primary reference for GRP tanks, other standards like BS 6920 dictate the chemical safety of materials touching your water. These rules aren't just suggestions; they’re the baseline for preventing bacterial growth and structural failure. Depending on whether you’re installing a small loft cistern or a massive sectional tank, the technical requirements for pressure and load-bearing shift significantly.
Key numbers
| Standard | Focus Area |
|---|---|
| BS EN 13280 | GRP cistern design |
| BS 6920 | Water quality/hygiene |
| BS EN 806 | Installation practices |
What are the primary British Standards (BS) governing the design and construction of cold water storage cisterns?
Beyond BS EN 13280, cold water storage cisterns must comply with the Water Supply (Water Fittings) Regulations 1999, which provide the legal framework for preventing contamination. Many people assume that any plastic tank sold at a hardware store is suitable for storing drinking water, but this is a dangerous error. Only tanks specifically tested and certified for potable water, often indicated by WRAS approval, are permitted for connection to the mains. Using a standard agricultural or industrial tank for domestic supply is a direct breach of these regulations.
What are the mandatory safety and hygiene requirements for materials in contact with drinking water under BS 6920?
BS 6920 mandates that any material in contact with drinking water must not cause an unacceptable change in water quality. This involves rigorous laboratory testing to check for the leaching of metals, the growth of microorganisms, and the extraction of substances that could affect the appearance, taste, or odor of the water. An example of this is the requirement for a long-term soak test, where samples are immersed in water to simulate real-world usage conditions and then analyzed for chemical migration.
An important nuance exists regarding the scope of these tests. While the standard covers the tank walls and internal components, it does not automatically certify the entire assembly if external parts, such as non-compliant gaskets or sealants, are introduced during site installation. Practitioners must verify that every individual component, including jointing compounds and flexible hoses, holds its own certification to maintain the integrity of the total system.
How do British Standards define the structural integrity and load-bearing capacity for sectional water tanks?
Yes, sectional tanks must undergo rigorous deflection tests where they are filled to their maximum working capacity plus a safety factor of 1.5. The panels must show no signs of permanent deformation or leakage under this load to meet the structural requirements.
What guidelines do British Standards provide for the installation and maintenance of domestic water storage tanks?
Installation guidelines focus on ensuring that tanks are accessible for periodic inspection and cleaning while maintaining the structural stability of the storage environment.
- 1 meter: This minimum clearance should be maintained around the tank perimeter to allow for maintenance access and visual inspection of joints.
- Level base: The supporting plinth must be perfectly flat and capable of bearing the full weight of the tank when filled to its maximum capacity.
- Thermal insulation: Tanks located in unheated spaces like lofts require adequate lagging to prevent freezing during winter months and heat gain in summer.
- Ventilation: The tank lid must include a screened vent to allow air movement without permitting the entry of insects or debris.
How does the British standard address the prevention of contamination and the necessity of air gaps in tank design?
The prevention of contamination relies on the physical separation of the water supply from potential pollutants, primarily through the use of an air gap. An air gap acts as a mechanical break, ensuring that if the water level in the tank rises or if a vacuum occurs in the supply pipe, water cannot be siphoned back into the public mains. For instance, a type AB air gap provides a physical break that is considered the most reliable method for protecting the mains against backflow in high-risk scenarios.
There is a notable exception regarding the size of this gap. The required distance is determined by the diameter of the supply pipe and the level of risk associated with the tank’s location. In domestic settings, a smaller gap might be permitted if the tank is not subject to high-risk contamination, but any reduction in the mandated air gap distance must be calculated based on specific regulatory tables rather than guesswork or convenience.
What are the testing protocols required by British Standards to verify the durability of water storage systems?
Testing protocols involve subjecting tanks to a hydrostatic pressure test at 1.5 times the maximum working pressure for at least 30 minutes. This confirms that the joints and panels remain watertight and structurally sound under stress, ensuring long-term durability in the field.
Mistakes to avoid
- Ignoring the air gap. People often install tanks without the required air gap, which risks backflow contamination into the mains supply.
- Using non-potable materials. Installing tanks not certified under BS 6920 can lead to chemical leaching and failed water safety tests.
- Neglecting structural support. Placing heavy sectional tanks on uneven surfaces leads to stress fractures that compromise the tank's integrity over time.
How do current British Standards align with international ISO requirements for water storage vessel manufacturing?
British standards are largely harmonized with ISO requirements, ensuring that domestic manufacturing benchmarks align with global quality expectations for water storage vessels.
| Metric | BS EN 13280 | ISO Equivalent |
|---|---|---|
| Pressure test | 1.5x working | 1.5x working |
| Material safety | BS 6920 | ISO 16421 |
| Design life | 25 years | 25 years |
Use these figures as a baseline for verifying that imported components meet the same structural and safety criteria as locally manufactured tanks.
Maintaining Your Water Storage System
Verify that every component of your storage system carries the appropriate British Standard certification before installation. Regular inspections of the tank’s interior and structural seals will help you avoid long-term contamination issues and premature system failure.